ILP and Register Renaming
Prerequisites: 02-Pipelining-and-Hazards Learning Goals: Understand ILP as an upper bound on processor parallelism, how register renaming removes false dependencies, and how ILP relates to actual IPC.
Instruction-Level Parallelism (ILP)
ILP = the maximum number of instructions that can be executed per cycle in an ideal processor.
- ILP is a property of the program, not the processor
- Computed assuming: perfect processor, infinite execution units, perfect branch prediction, no structural limits
\text{ILP} = \frac{\text{# Instructions}}{\text{# Cycles required (ideal)}}
ILP ≥ IPC always — real processor constraints reduce IPC below the ILP upper bound.
The Execute Stage and Forwarding
- Forwarding can supply data in the next cycle after production, not the same cycle
- For a RAW dependency: the reading instruction must be delayed by at least 1 cycle to allow the write to complete
Types of Dependencies Recap
| Type | True/False | Impact on CPI |
|---|---|---|
| RAW | True | Directly limits CPI |
| WAW | False (Name) | Can cause OOO issues |
| WAR | False (Name) | Can cause stalls |
- CPI is primarily determined by RAW dependencies
- WAW can cause incorrect results in out-of-order execution if not handled
- WAR and WAW are called false or name dependencies because they arise from reusing the same register name, not from a genuine data flow
Removing False Dependencies
Why False Dependencies Exist
Two instructions use the same register to hold different, unrelated values. The processor sees a “conflict” even though there is no actual data flow between them.
Method: Register Renaming
Architectural registers: registers visible to the programmer (e.g., R0–R31) Physical registers: all storage locations available in hardware (more than architectural)
The processor maps architectural registers to physical registers dynamically, giving each instruction write a fresh physical register. This eliminates WAW and WAR conflicts.
Register Allocation Table (RAT)
The RAT tracks which physical register currently holds the value for each architectural register.
How RAT Works
- Each entry:
architectural register → physical register (or "register file") - When an instruction writes to an architectural register:
- Allocate a new physical register
- Update the RAT entry for that architectural register
- When an instruction reads a register:
- Look up the RAT → get the physical register holding the current value
Effect of Renaming
- WAR eliminated: reader uses the old physical register; writer gets a new one
- WAW eliminated: each write goes to a different physical register
- RAW preserved: the RAT correctly chains reads to the latest write
Renaming improves CPI and IPC by removing artificial stalls caused by false dependencies.
Steps to Compute ILP
- Rename registers as they are written, tracking which physical registers are free
- “Execute” the program assuming infinite resources and no false dependencies
- Determine the earliest cycle each instruction can execute given only true (RAW) dependencies
- ILP = Instructions / Cycles
ILP with Control Dependencies
- Structural dependencies do not apply to ILP (perfect processor has unlimited units)
- For control dependencies: assume perfect branch prediction — all branches are resolved instantly with no mispredictions
ILP vs. IPC
| Metric | Processor Model | Branch Prediction | Issue Width |
|---|---|---|---|
| ILP | Ideal, infinite | Perfect | Infinite |
| IPC | Real, limited | Real predictor | Finite N |
ILP is always ≥ IPC. The gap between them comes from:
- Finite issue width
- In-order constraints
- Imperfect branch prediction
- Structural limitations
In-Order vs. Out-of-Order
| Processor Type | Limiting Factor |
|---|---|
| In-order, narrow issue | Issue width (narrow issue is more limiting than in-order) |
| In-order, wide issue | In-order constraint (more limiting than width) |
If a processor can issue 4+ instructions per cycle (wide-issue), it should also be out-of-order to fully exploit the width. It also needs register renaming to eliminate false dependencies.
Summary
Key Takeaways:
- ILP is the program’s inherent parallelism — the ideal upper bound
- RAW = true dependency; limits ILP/IPC regardless of renaming
- WAW/WAR = false dependencies; can be eliminated with register renaming
- The RAT maps architectural → physical registers, enabling renaming
- Wide-issue processors need OOO + renaming to be effective
Common Patterns:
- Compute ILP: rename registers, identify earliest execution cycle per instruction
- RAT table exercise: trace through Issue/Rename/Read for each instruction